Tag Archives: perth bore sand

Old bore pumping sand

We were called to repair an old well that was pumping sand in Mount Pleasant.

The spear has collapsed in the old well and it was producing sand blocking pipes and the solenoid valves.

The most economical solution for the Mt Pleasant home was to replace with a new submersible water bore.

Trying to fix old bore pumping sand This old bore well is pumping sand

Here we are looking for the solenoids for the reconnection to the new Mount Pleasant water bore.

If you are in the Mt Pleasant, Applecross or Ardross area and are thinking about a water bore call 9246 0111 or read more about your new submersible bore HERE

Bore pumping sand?

We called on a client today in Attadale.

He had sand coming out of his old submersible bore and blocking sprinklers. Three scenarios spring to mind.  (1) Worst case it could be that the  screen at the bottom of the submersible bore has been perforated or cracked to such an extent it lets sand in. This would most likely mean a new bore hole would need to be drilled. Sometimes though, we try setting the submersible pump inlet higher up the casing with some success. (2) Sometimes we find the check valve on the submersible pump is no longer holding prime whilst at the same time there is a faulty solenoid valve, open gate valve or cracked irrigation main line that causes sand to be sucked back down the rising main when the pump is turned off.  (3) there is ingress of dry sand falling down an incorrectly covered  bore head or wet sand being washed down with incorrect bore head exposure and drainage. There are other reasons. All can be addressed.

For old well style bores there are different reasons again that we will cover in another blog.

In the meantime if you are in Perth or surrounds and you need help with any bore problem give us a call on 9246 0111 or visit our main website.