Tag Archives: retic

Automation of Old Well

This old well with a tin lid has been running without a retic controller. We are going to automate this old well in Morley.

We will fit an automatic reticulation controller and interface to the clients existing on/off switch. We then replace the manual bore valves (in the foreground of the picture) with automatic solenoid valves.

Hey presto, it will come on automatically and switch from front to rear lawns and it is fully programmable.

If we can help you with a similar issue or anything to do with your bore or reticulation contact one of our friendly team on 9246 0111 or go to our website HERE

Automate old well
Automate old we

Lowara bore pump problem in Perth?

Lowara bore start box

Lowara submersible pumps and motors are a good reliable Italian brand but, like anything, they can have their own idiosyncracies. We specialise in servicing Lowara submersible pumps and their stablemates, Centripro and Marlow. We have over a decade of practical in-the-field service and pump repair experience. A problem that does from time to time present itself with some of the earlier Lowara single phase motors is blown start capacitors in the bore start box. It is an easy fix for someone experienced in Lowara pumps and motors. Give our Perth bore service and repair hotline a call on 1300 734 300 and our mobile bore service team can help you. Or visit or main Virgin Bores website for more bore info and help.

Bore light stays on?

Familiar call today from a lady who happened to live in Sorrento, but we get similar calls from bore owners all over Perth. “the light on my bore box on the wall has stayed on even after I have turned the reticulation controller off “.  This can turn in to a bigger problem so first things first, if you are reading this blog and your bore box light is on but there is no water pumping out anywhere please straight away turn the bore mains power off.  Turn it off by either turning off the circuit breaker ( or pulling the fuse) labelled “bore” or “pump” that you will hopefully see in your meter box. Or turn off the bore box isolation switch that is located on the bore box on the wall. ( this is called a bore start box, not to be confused with the reticulation controller). Worst case if you can’t turn it by either of these two methods then turn off your mains power master switch and call us pronto on 1300 734 300.

Lowara bore start box

What has most likely happened is that your automatic reticulation controller has correctly sent the 24 volt start signal to the relay in the bore start box and this has started the 240v bore at the same time as the reticulation controller has correctly sent a signal to open a solenoid valve allowing water to flow to the sprinklers. All good so far but then when the automatic reticulation controller has run through its cycle and shut the last solenoid valve the pump has continued to run. Most likely the start relay has stuck on and needs replacing. Prolonged operation of any bore pump with no water being able to flow (dead heading ) can cause a multitude of problems. Most commonly with submersible pumps the rising poly mainline will overheat and “blow”. With centrifugal well pumps overheating leads to several serious problems. Give our Perth bore service hotline a call on 1300 734 300 or visit our main website for more help on bores and reticulation.

Bore Pump stopped working?

Check the pump circuitbreaker or fuse.

Seems today was “D” Day with many Perth bore owners turning their water bores on for the first time this season….or should I say trying to turn them on. Calls today from Joondalup, Floreat, Landsdale, Safety Bay and Armadale all with a similar story. Either the pump cicuitbreaker was tripping ( or fuse blowing ) when the bore was turned on or nothing was happening at all. Some simple tests and solutions can be found in our Perth bore troubleshooting guide in this blog or call our Perth Bore Service Hotline    1300 734 300      Perth metro-wide    All Suburbs     We are specialists in both water bores and reticulation ( irrigation ) systems so whatever your problem we can fix it!