Bore problem Greenwood

Pat lives in Greenwood and her RCD (Residual Current Device) switch was tripping.  (It was the RCD rather than the circuit breaker tripping ) Who did she call? Us on 9246 0111.

We sent out our experienced bore electrician, Dave.

The first thing he did was test the submersible water bore motor and it tested OK. There was one RCD that protected all power points on two circuits with the pump on the power circuit.

We fixed RCD that was tripping while retic being used
A customer’s RCD was tripping when she was using her retic

Bore was tripping when retic ran.

Pat told us that when station 3 was on the RCD tripped. Dave noticed there was a broken sprinkler right near the bore head washing out sand.

img_9208-1

He exposed the bore head and it was filled with sand which he dug out by hand. Sand should not cover the top of a submersible bore for a variety of reasons. It can drop down inside the bore casing and as it is pumped back out it will prematurely wear  out the pump impellers. It can also play havoc with solenoid valves in the retic system.

But why was this bore tripping?

As Dave dig down he exposed the electrical junction box that joined the cables up from the pump with those going towards the house. It appears that as the sand got wet from the broken sprinkler the moisture was getting in to the less than perfect electrical junction box and causing the bore RCD to trip. Upon removing the sand and retesting all worked OK.  It has been noted though that the j box will need replacing and raising whenever the submersible motor is replaced.

img_9204
Submersible Bores should never be covered by sand

This Greenwood garden bore and retic system is now working OK.

Can we help you repair your modern submersible water bore? Call us on 9246 0111 or book a bore Repair here

Bore Repair Lockridge

We have nearly 20 years experience in installing, repairing and servicing water bores in the Perth Metropolitan area. This means we have a depth of knowledge and experience to tackle any challenge.

Reticulation Connection in Lockridge

BUT not all bore connections are as hard as this one in Lockridge!

Connect new bore to older reticulation connection
Lockridge reticulation has to be connected to new bore

Our client was a church in Lockridge. We drilled a modern submersible water bore replacing their old style well with a tin lid.

Jack disconnected this retic system from the old bore and connected it to the new submersible bore we have just drilled.

As you can see all the fittings were waist deep in an old pit. Not pretty but nice work Jack!

Lockridge water bore connection to reticulation
Connection of old reticulation system to new water bore

So anywhere in the area Lockridge, Eden Hill or Kiara if you your water bore needs repair or you would like a new submersible water bore, call us on 9246 0111 or go to our website here

Gravel Packing Water Bore

 

To safeguard the construction of a modern submersible water bore in the Perth metropolitan area water bores should be gravel packed. Read more about gravel packing water bores HERE

To help keep sands and silts out of a modern domestic water bore we use driller’s gravel. Gravel packing a modern submersible water bore is an important part of good bore construction.

If you have been thinking about a Perth water bore to save money and have the best garden in the street call us on 9246 0111

My submersible pump running with no water

My submersible pump running with no water

My submersible pump running with no water


— Read on waterboretroubleshootersperth.com/2013/09/14/i-know-my-submersible-pump-is-running-but-no-water/

Repair Submersible Water Bore Gosnells

 

Chris lives in Gosnells and his modern submersible water bore 2 horsepower 3 phase motor was tripping.

We sent in our specialist bore electrician Dave to test the motor and it tested fusion.

As you can see the bore head has a large gate valve so it took a bit of digging and mucking around.

Adam then returned and replaced the 1.5 KW 3 phase motor, wet-end and cable.

Dave then returned and fitted new junction box. He ran and tested and all OK

Chris Gosnells Borehead

Thanks so much to Chris for the following review. We are a family run and have been in the business for nearly 20 years and love to look after our customers,

Chris Gosnells Review

If we can help you call us on 9246 0111 or we can call you

Replace Reticulation Controller Hillarys

 

Our service teams have fully stocked vans and are on the road ready to repair your modern submersible bore or reticulation systems in all Perth suburbs.

Our specialist service team was fully stocked for this job to replace an eight station controller in the beautiful Perth coastal suburb of Hillarys.

Replacing retic controller
Retic controller needs replacing

We replaced this 8 station controller for new and programmed the new controller for the client at 6am three days a week. The client has a water bore so is able to water their garden and lawn 3 days a week whereas householders on mains water can only water 2 days a week.

Irragation Australia

Replacing Hillary's retic controller
Hillary’s retic controller

If your reticulation controller needs replacing give us a call on 9246 0111 for prompt and economical service or we can call you

Repair Water Bore Leeming

Mel asked us to look at the modern submersible water bore at his son’s house south of the river in Leeming.

Top of water bore in Leeming
Leeming submersible water bore

We sent our specialist bore electrician Dave to do a range of tests to work out the problem. He tested the single phase two wire submersible motor and found it was fused. The motor start winding is damaged by rupture of internal capacitor.

In some cases a fused motor can be claimed on the householders insurance.

Repair water bore Leeming

Our service teams will return to replace the motor so the householders bore and reticulation will be up and running.

If your modern submersible water bore needs repair south of the river call us on 9246 0111 or we will ring you about your bore repair

Bore Not Starting Tapping

Mark from Tapping phoned us on 9246 0111 to say his bore was not working.

We sent our specialist bore electrician Dave to test the single phase two wire motor which tested OK. Good news!

Borehead of Tapping water bore
Top of Tapping water bore

He found the 24 volt relay was faulty and replaced it for new. All is working again on 3 stations with all readings OK.

Tapping water bore repaired
Tests OK after relay replaced

If you live in the Tapping area or the surrounding suburbs of Wanneroo, Banksia Grove or Joondallup and your modern submersible water bore or old well is not working and needs repair call us on 9246 0111

FYI (source Wikipedia)

Tapping is a suburb of Perth, Western Australia, located within the City of Wanneroo. It came into being in the early 1990s as a subdivision of Wanneroo, originally as part of the Carramar estate. Tapping was chosen as the suburb name in honour of an early settler family in the Wanneroo area. Mr William Tapping arrived in 1886 and Molly and Dolly Tapping were long time Postmistresses in Wanneroo. The name for the suburb was approved in 1997.

Repair Old Well Queens Park

Dave our specialist bore electrician attended a job in Queens Park where it was reported the centrifugal pump for an old well wasn’t working.

The single phase Davey Boremaster tested OK so he replaced the 30 mf capacitor for new and the water bore is working again.

img_7425.jpg

However he did note on his report that there were distinct mechanical sounds and he was not sure how long the pump would last before it fails mechanically.

If your old well water bore needs repair and you are in Queens Park or the surrounding areas of Welshpool, Cannington or Bentley call us on 9246 0111 or check out our website

Repair Water Bore Trigg

The modern submersible water bore at property in the Perth coastal suburb of Trigg wasn’t working.

The reticulation controller seemed normal and the green light on side of bore start box was still coming on. Nothing tripping in meter box.

The man for the job was Dave, our bore electrician, who has been solving these sorts of mysteries for years.

He tested everything and found the fault with the illuminated green rocker switch on the bore control box

He isolated it and this Trigg modern submersible water bore and the reticulation now working with crystal clear water.

 

If your water bore needs repair call us on 9246 0111 or we will call you