Replace Reticulation Controller Hillarys

 

Our service teams have fully stocked vans and are on the road ready to repair your modern submersible bore or reticulation systems in all Perth suburbs.

Our specialist service team was fully stocked for this job to replace an eight station controller in the beautiful Perth coastal suburb of Hillarys.

Replacing retic controller
Retic controller needs replacing

We replaced this 8 station controller for new and programmed the new controller for the client at 6am three days a week. The client has a water bore so is able to water their garden and lawn 3 days a week whereas householders on mains water can only water 2 days a week.

Irragation Australia

Replacing Hillary's retic controller
Hillary’s retic controller

If your reticulation controller needs replacing give us a call on 9246 0111 for prompt and economical service or we can call you

Repair Water Bore Leeming

Mel asked us to look at the modern submersible water bore at his son’s house south of the river in Leeming.

Top of water bore in Leeming
Leeming submersible water bore

We sent our specialist bore electrician Dave to do a range of tests to work out the problem. He tested the single phase two wire submersible motor and found it was fused. The motor start winding is damaged by rupture of internal capacitor.

In some cases a fused motor can be claimed on the householders insurance.

Repair water bore Leeming

Our service teams will return to replace the motor so the householders bore and reticulation will be up and running.

If your modern submersible water bore needs repair south of the river call us on 9246 0111 or we will ring you about your bore repair

Bore Not Starting Tapping

Mark from Tapping phoned us on 9246 0111 to say his bore was not working.

We sent our specialist bore electrician Dave to test the single phase two wire motor which tested OK. Good news!

Borehead of Tapping water bore
Top of Tapping water bore

He found the 24 volt relay was faulty and replaced it for new. All is working again on 3 stations with all readings OK.

Tapping water bore repaired
Tests OK after relay replaced

If you live in the Tapping area or the surrounding suburbs of Wanneroo, Banksia Grove or Joondallup and your modern submersible water bore or old well is not working and needs repair call us on 9246 0111

FYI (source Wikipedia)

Tapping is a suburb of Perth, Western Australia, located within the City of Wanneroo. It came into being in the early 1990s as a subdivision of Wanneroo, originally as part of the Carramar estate. Tapping was chosen as the suburb name in honour of an early settler family in the Wanneroo area. Mr William Tapping arrived in 1886 and Molly and Dolly Tapping were long time Postmistresses in Wanneroo. The name for the suburb was approved in 1997.

Repair Old Well Queens Park

Dave our specialist bore electrician attended a job in Queens Park where it was reported the centrifugal pump for an old well wasn’t working.

The single phase Davey Boremaster tested OK so he replaced the 30 mf capacitor for new and the water bore is working again.

img_7425.jpg

However he did note on his report that there were distinct mechanical sounds and he was not sure how long the pump would last before it fails mechanically.

If your old well water bore needs repair and you are in Queens Park or the surrounding areas of Welshpool, Cannington or Bentley call us on 9246 0111 or check out our website

Lawn Care in Perth

“Gardening in Western Australia” is a booklet produced by the Western Australian Newspapers. We are not sure when but needless to say it was a long time ago.

We found it in the office while doing a clean up and it is a lovely read.

Some of the subjects covered included fertilizer, growing annuals, trees & shrubs, Camellias & Azaleas deserve popularity, getting the best out of fruit trees & the kitchen garden.

In one articles on lawn care by Nick Bell, we love the description of a domestic lawn as “the vibrantly beautiful carpet of the out-door living room

Garden Mag 2

This City Beach lawn looks fantastic.

In 2019 we can care for your gardens and lawn with modern submersible water bores & modern reticulation systems. We install and repair all over the Perth metro area.

Call us on 9246 0111 read more about us here

Fix Old Bore Yangebup

One of our recent bore repair jobs was a centrifugal pump motor tripping the circuit breaker in the backyard of this property in Yangebup. You can see the rusted and partially collapsed tin lid of the bore well in this picture.

Bore safety

As an aside it reminded us all old style bore well lids should be secured. Take a look here on bore safety.

Tin lid of old well in backyard of a property in Yangebup
Yangebup old bore needs fixing

Dave, our specialist bore and pump electrician attended the job and found there was a 3 liner well with bore pump located on wooden boards 2 liners down.

Fix 3 liner well Yangebup
3 liner  bore well Yangebup

 

Pump failed mechanically

The 3 phase pump and motor had failed mechanically and was just humming. The pump had not fused and was fine electrically but need replacement.

We returned and supplied and installed a 2.2 kW 3 phase centrifugal pump and fittings.

Our customer now has bore water again.

Mobile bore repairs

If you are in Yangebup or the surrounding areas of South Lake, Bibra Lake or Spearwood and your old bore well needs repair call us on 9246 0111 or book your repairs here

Bore Repair Armadale

Patrick from Armadale rang us on 9246 0111 when his submersible pump motor was not working.

We sent our specialist bore electrician, Dave.

Bore control in roof space

The Franklin Electric 1.5 kW  single phase bore pump start box was in the roof space with 24 volt relay behind meter box panel. This is a very unusual place to find the bore  controls as the start box contains the capacitor and overload circuits. Also unorthodox place to position the 24 volt relay that accepts the start signal from the retic controller.

Pump running but no water

The pump motor was running but only drawing 7.7amps which is more consistent with  a 1.1kW not a 1.5kW submersible pump motor.

Top of submersible bore under lawn

Dave exposed the bore head which was located in the front lawn. The top of the bore was just under the lawn with the typical green lid. There was no barrel union (threaded coupling) so he drilled a small hole in the top of the PVC pipe connected to the retic system and found there was no water in it as would be normal. This could signify a check valve failed in the pump or a blown poly line that brings the bore water to the surface.

Return to pull out submersible pump

Our next step will be to winch up the pump motor to investigate further and then repair this Armadale water bore. Our submersible pump winch team is booked to return.

If you are in the Armadale area or any Perth suburb and your water bore needs repair call us on 9246 0111 or book your bore repair here

Repair Water Bore Mindarie

One of our recent jobs involved a submersible pump motor not working. We had installed the modern submersible water bore in 2005.

Dave our specialist bore electrician was the man for the job. He attended at the Mindarie home and tested the 1.5KW pump motor and it tested OK.

As you can see here it was a blown 50 MF Capacitor. He replaced for new and the customer’s water bore is up and running without too much trouble or cost.

If you live in Mindarie or the surrounding suburbs of Clarkson or Quinns Rock we have been repairing water bore in Perth’s coastal suburbs for years. If your water bore needs repair call us on 9246 0111 or book a bore service online

My solenoid is sticking open

A common problem in garden reticulation systems is solenoids sticking open. Read on for some DIY tips.

A customer that rang yesterday has reticulation off the mains and one of his solenoid valves was sticking open. His sprinklers were stuck on continuously unless he turned his water meter off. We explained over the phone how to locate their isolation gate valve so he could  turn off just his reticulation system until the problem was fixed.

HERE is a great “how to” find the solenoid valve guide with lots of facts and information of finding lost solenoids and what to do if they are sticking open.  It also contains tips on where the main retic shut off valve or tap should be,

The customer sent us this picture once they had found the gate valve. This main shut off valve shows an unorthodox connection with typical red wheel handle missing from the gate valve.

Isolation Valve

The customer was grateful for the assistance we were able to give over the telephone “Found and isolated. Thanks to you and your excellent website. We only moved in last December and my wife wants to redo the gardens so expect a call soon(ish) to renovate the entire reticulation system”

Thanks very much we are happy to help!

Note that some isolating  gate valves will have a red “wagon wheel” handle and when buried in moist sand these often become brittle and rusted over the years. Sometimes attempting to turn the valve breaks of the handle and a pair of multi-grips is called for to twist the shaft.

If you have lost your solenoid valve or it is broken call us on 9246 0111 and we will be happy to help you

 

 

Replace Centrifugal Pump Perth

This old centrifugal pump was in a shallow 3 liner well style bore in Perth.

We can repair the old style wells up to 4 liners deep. We replaced this pump with a new pump.

The old style wells with concrete liners have tin “witches hat” style lids and the pump is visible once you lift the lid.

We stock compatible replacements for most brands of centrifugal pumps including, Onga, Davey, Calpeda, Weststate, Lowara and Stalker.

Call us 7 days on 9246 0111 if your old style well needs repair or book a call back on line here.