Bore Not Starting Tapping

Mark from Tapping phoned us on 9246 0111 to say his bore was not working.

We sent our specialist bore electrician Dave to test the single phase two wire motor which tested OK. Good news!

Borehead of Tapping water bore
Top of Tapping water bore

He found the 24 volt relay was faulty and replaced it for new. All is working again on 3 stations with all readings OK.

Tapping water bore repaired
Tests OK after relay replaced

If you live in the Tapping area or the surrounding suburbs of Wanneroo, Banksia Grove or Joondallup and your modern submersible water bore or old well is not working and needs repair call us on 9246 0111

FYI (source Wikipedia)

Tapping is a suburb of Perth, Western Australia, located within the City of Wanneroo. It came into being in the early 1990s as a subdivision of Wanneroo, originally as part of the Carramar estate. Tapping was chosen as the suburb name in honour of an early settler family in the Wanneroo area. Mr William Tapping arrived in 1886 and Molly and Dolly Tapping were long time Postmistresses in Wanneroo. The name for the suburb was approved in 1997.

Repair Old Well Queens Park

Dave our specialist bore electrician attended a job in Queens Park where it was reported the centrifugal pump for an old well wasn’t working.

The single phase Davey Boremaster tested OK so he replaced the 30 mf capacitor for new and the water bore is working again.

img_7425.jpg

However he did note on his report that there were distinct mechanical sounds and he was not sure how long the pump would last before it fails mechanically.

If your old well water bore needs repair and you are in Queens Park or the surrounding areas of Welshpool, Cannington or Bentley call us on 9246 0111 or check out our website

Repair Water Bore Trigg

The modern submersible water bore at property in the Perth coastal suburb of Trigg wasn’t working.

The reticulation controller seemed normal and the green light on side of bore start box was still coming on. Nothing tripping in meter box.

The man for the job was Dave, our bore electrician, who has been solving these sorts of mysteries for years.

He tested everything and found the fault with the illuminated green rocker switch on the bore control box

He isolated it and this Trigg modern submersible water bore and the reticulation now working with crystal clear water.

 

If your water bore needs repair call us on 9246 0111 or we will call you

Repair Well Noranda

One of our jobs this week was from a customer in Noranda whose tripping centrifugal pump motor needed repair.

We sent Dave our specialist bore electrician who tested the single phase Lowara pump motor. It tested OK.

Pump motor of old well in Noranda
Noranda Lowara centrifugal pump motor

On further investtigation he found the 50mF capacitor was faulty so replaced it with a new 45mF capacitor. He replaced the 9V battery for new in the controller.

Why is it important to replace the 9V battery in the reticulation controller?

Retic controllers have batteries to preserve the memory that has been programmed in the event of a mains power fail.

The battery is normally only 9 volts and does not have the power to operate solenoid valves or pump start relays. Solenoid valves and most other irrigation devices operate on 24 volts. Most retic controllers are 240 volt mains powered with a transformer that steps down to 24 volt to operate the individual irrigation devices. It may seem like a minor inconvenience if you have a flat 9 volt battery in your controller as at first glance one would think it is not a big issue if you lose mains power and the controller has to be reprogrammed.

BUT it can have nasty consequences if the controller operates a bore.

If mains power is lost to quite a few brands of reticulation controllers and there is no back up battery then when mains power is restored the controller resets all programming to factory default which is often 10 minutes per station per day. This may then turn the bore on to stations that don’t exist and the pump runs with nowhere for the water to go. This can damage the pump or pipe work of the bore.

Old Style Well in Noranda is repaired

Dave reprogrammed the controller for the customer for their watering days of Tuesday, Thursday and Sunday.

The Noranda customer’s old style well is repaired and they have water.

If you live in Noranda or the surrounding areas of Morley or Dianella and your old bore needs repair call us on 9246 0111 or learn more here

Fix Old Bore Yangebup

One of our recent bore repair jobs was a centrifugal pump motor tripping the circuit breaker in the backyard of this property in Yangebup. You can see the rusted and partially collapsed tin lid of the bore well in this picture.

Bore safety

As an aside it reminded us all old style bore well lids should be secured. Take a look here on bore safety.

Tin lid of old well in backyard of a property in Yangebup
Yangebup old bore needs fixing

Dave, our specialist bore and pump electrician attended the job and found there was a 3 liner well with bore pump located on wooden boards 2 liners down.

Fix 3 liner well Yangebup
3 liner  bore well Yangebup

 

Pump failed mechanically

The 3 phase pump and motor had failed mechanically and was just humming. The pump had not fused and was fine electrically but need replacement.

We returned and supplied and installed a 2.2 kW 3 phase centrifugal pump and fittings.

Our customer now has bore water again.

Mobile bore repairs

If you are in Yangebup or the surrounding areas of South Lake, Bibra Lake or Spearwood and your old bore well needs repair call us on 9246 0111 or book your repairs here

Bore Repair Armadale

Patrick from Armadale rang us on 9246 0111 when his submersible pump motor was not working.

We sent our specialist bore electrician, Dave.

Bore control in roof space

The Franklin Electric 1.5 kW  single phase bore pump start box was in the roof space with 24 volt relay behind meter box panel. This is a very unusual place to find the bore  controls as the start box contains the capacitor and overload circuits. Also unorthodox place to position the 24 volt relay that accepts the start signal from the retic controller.

Pump running but no water

The pump motor was running but only drawing 7.7amps which is more consistent with  a 1.1kW not a 1.5kW submersible pump motor.

Top of submersible bore under lawn

Dave exposed the bore head which was located in the front lawn. The top of the bore was just under the lawn with the typical green lid. There was no barrel union (threaded coupling) so he drilled a small hole in the top of the PVC pipe connected to the retic system and found there was no water in it as would be normal. This could signify a check valve failed in the pump or a blown poly line that brings the bore water to the surface.

Return to pull out submersible pump

Our next step will be to winch up the pump motor to investigate further and then repair this Armadale water bore. Our submersible pump winch team is booked to return.

If you are in the Armadale area or any Perth suburb and your water bore needs repair call us on 9246 0111 or book your bore repair here

Repair Water Bore Mindarie

One of our recent jobs involved a submersible pump motor not working. We had installed the modern submersible water bore in 2005.

Dave our specialist bore electrician was the man for the job. He attended at the Mindarie home and tested the 1.5KW pump motor and it tested OK.

As you can see here it was a blown 50 MF Capacitor. He replaced for new and the customer’s water bore is up and running without too much trouble or cost.

If you live in Mindarie or the surrounding suburbs of Clarkson or Quinns Rock we have been repairing water bore in Perth’s coastal suburbs for years. If your water bore needs repair call us on 9246 0111 or book a bore service online

Water Bore Repair Electrical

Often we get called to bore pump problems where customers have been told by someone, even by electricians, that the problem “must be the pump” and it needs replacing.

There can be a vast number of reasons why your water bore is not working. If you call on 9246 0111 we will talk you through the problem over the phone. We will then send the correct person to diagnose/fix your water bore.

If we think it is an electrical problem we will send one of our specialist bore electricians.

Electrical problem with domestic water bore Perth
Our specialist electrician fixing water bore

It can be hard for the inexperienced to diagnose bore pump faults particularly with submersible pumps. Often though we find on closer examination it is a control equipment or wiring issue. Our specialist bore electrician tracks down faults and repairs bores, retic and pumps on a daily basis. We have the correct diagnostic equipment and years of experience so we will save you time and money.

If your water bore needs repair call us on 9246 0111 or BOOK A BORE SERVICE HERE

My solenoid is sticking open

A common problem in garden reticulation systems is solenoids sticking open. Read on for some DIY tips.

A customer that rang yesterday has reticulation off the mains and one of his solenoid valves was sticking open. His sprinklers were stuck on continuously unless he turned his water meter off. We explained over the phone how to locate their isolation gate valve so he could  turn off just his reticulation system until the problem was fixed.

HERE is a great “how to” find the solenoid valve guide with lots of facts and information of finding lost solenoids and what to do if they are sticking open.  It also contains tips on where the main retic shut off valve or tap should be,

The customer sent us this picture once they had found the gate valve. This main shut off valve shows an unorthodox connection with typical red wheel handle missing from the gate valve.

Isolation Valve

The customer was grateful for the assistance we were able to give over the telephone “Found and isolated. Thanks to you and your excellent website. We only moved in last December and my wife wants to redo the gardens so expect a call soon(ish) to renovate the entire reticulation system”

Thanks very much we are happy to help!

Note that some isolating  gate valves will have a red “wagon wheel” handle and when buried in moist sand these often become brittle and rusted over the years. Sometimes attempting to turn the valve breaks of the handle and a pair of multi-grips is called for to twist the shaft.

If you have lost your solenoid valve or it is broken call us on 9246 0111 and we will be happy to help you

 

 

Replace Centrifugal Pump Perth

This old centrifugal pump was in a shallow 3 liner well style bore in Perth.

We can repair the old style wells up to 4 liners deep. We replaced this pump with a new pump.

The old style wells with concrete liners have tin “witches hat” style lids and the pump is visible once you lift the lid.

We stock compatible replacements for most brands of centrifugal pumps including, Onga, Davey, Calpeda, Weststate, Lowara and Stalker.

Call us 7 days on 9246 0111 if your old style well needs repair or book a call back on line here.