Tag Archives: bore repair

Why is my old Perth bore running out of water?

Some Perth bore owners are telling us their very old water bores are running out of water or that it runs for a minute or two then it runs out.  We can help on 9246 0111.

This can be a a problem with the reticulation system or with the pump.

Slotted PVC bore casing
Slotted PVC bore casing

 

Commonly it is an issue with the yield of the bore itself and the pump is pumping water out faster than it is flowing in to the bore casing.

Many people think the bore is not deep enough. At times the water table does drop & it is a depth related issue. More often the stainless steel bore screen or slotted PVC bore casing has become blocked. Sometimes the ground around the bore has reduced the water it will “allow” to flow through it.

We would try air-developing, a process where large volumes of compressed air are pumped down the bore. We can also chemically clean and restore the bore with a combination of special cleaning compounds, surfactants and clay dispersants.

If your old Perth water bore is running out of water call us on 9246 0111 and we will talk through the problem or book a service online

Water bore faulty Perth

The sprinkler bans in Perth end at the end of August. We encourage you to only start using your Perth sprinklers when the garden needs it.

Perth bore owners have been out testing their water bores for the first time this spring. Some are faulty!

Electrical fault water bore
Bore electrical specialist working on submersible bore

We are hearing similar stories like  “I’m starting my bore and the circuit breaker is tripping or fuse is blowing, what should I do?”. We would send our specialist bore electrician Dave who has been doing this for years and is expert and experienced with water bores. He has special equipment to test the circuits & windings of the motor. We can do this without winching the pump up.

We remind our customers that if it is a fused bore pump motor it may be covered under household insurance. Also if the fault is storm related even damage from lightning induction that then this too may be subject to an insurance claim.

Submersible water bore from surface
Top of submersible water bore

To have the matter attended to first by specialist bore repairers who can correctly diagnose the fault and possible cause call the team on 9246 0111 or book an online service and read more about faulty water bores HERE

Thanks Bore Electrician Kewdale and Pump Replacement Carine

It is great to hear from happy customers and hear good reviews. Thank you! 9246 0111

Thanks for sending our specialist bore electrician to Kewdale
Thanks for sending our specialist bore electrician to Kewdale

Our experienced bore electrician Dave attended Russell’s Kewdale property, checked his system and supplied and fitted a new reticulation controller.

We also attended Philip’s Carine property where we replaced his .75 kw 2 wire submersible motor / pump and tested that everything was OK.

“Thank you for your teams excellent work just prior to Christmas. Having the bore operational again has been fantastic. Once again thank you and I am happy to recommend your services to anyone. Regards Phillip.”

If we can assist you with specialist bore electrical advise or pump replacement visit our website  HERE or phone Troy (ask him how his fishing is going) on 9246 0111

Swollen Bore Pipe

Our Perth northern suburbs bore service man snapped this pic of a swollen PVC pipe in Duncraig.

Heat induced swollen PVC pipe
Heat from a centrifugal pump that ran without water deformed this PVC pipe.

The centrifugal pump in an old well had clearly been run without water flowing. The pump had consequently overheated causing the heat stress on the adjacent PVC and the resultant swelling. If you have any bore or well problem in Perth then please call us. Our mobile service teams are ready to help you north or south of the river.

We have equipped bore service vans on the road who can help you with any issues you may have with your bore or reticulation we can fix it quickly.

If you are in the northern suburbs and your bore needs repairing call Troy on 9246 0111  or book a bore service online

Old Well New Submersible Pump

This old well in Myaree has had a carport built over the top. We are looking at converting it to a submersible pump which will be accessed by a hatch in the new liquid limestone floor. Call 9246 0111.

Replace Myaree well with old tin lid
Old style well in Myaree to be replaced

If have been in the business nearly 20 years and have extensive knowledge in Myaree and the surrounding areas of Melville and Booragoon.

If you live in the Myaree area and have an old well and would like to consider a modern submersible water bore call us on 9246 0111 or go to our website HERE

Submersible Bore Pump Shaft Broken

We had an unusual service call yesterday  (9246 0111) about a submersible bore pump that was producing only about 25% of the water that it normally delivered.

submersible pump shaft
Pump and motor uncoupled showing shaft.

We ruled out all the normal things like a hole in the poly rising main, pump wasn’t running backwards, none of the “normal” causes.???  When we winched the submersible pump to the surface we found the shaft joining the motor to the “wet-end” (pump) seemed OK but on uncoupling the submersible pump we noted inconsistencies. Found the shaft had sheared actually inside the pump leaving the first 4 of 12 impellers still turning. Quite an uncommon fault.

submersible pump
Submersible pump shaft snapped

Further detective work found the unusual auto start device had been turning the pump on/off, on/off incessantly contributing to the failure. Replaced the pump and installed it all back down the borehole with the original motor. Tested and all good now!

We have been in the water boring business for nearly 20 years and know how to repair and service water bores in Perth. We are a family business and will look after you.

Call us anytime on  9246  0111 or Troy on mobile 0408 454 130. Our mobile bore service teams visit all Perth suburbs.

There is more information on water bores in Perth HERE

Bore and Retic Service – Experience Pays

We uncovered this curious old valve in a job south of the river. The younger retic serviceman on the job had never seen one before.

They are actually a Fimco Hydro Indexing Valve rarely seen in Perth home reticulation systems anymore.  This model can handle 4 zones or stations on a reticulation system. These cam-operated valves were used to split up the water delivery from some older well style bores around Perth. No wires or electronics involved.

Indexing valve old style
Old style indexing valve

 

Each time the bore started the valve opening would move around to divert water to one of four downward facing delivery pipes that can’t be seen clearly in this picture.

We have the knowledge and experience to solve any Perth bore or reticulation problem. You can visit our main website here or call 9246 0111 to book a service visit.

How do I know if my submersible pump motor is a “2 wire” or a “3 wire”?

Franklin start box
Franklin start box

This terminology is used to describe the single phase motor that drives the submersible “wet-end” or pump. It is not used in reference to three phase submersible pumps. The difference between a “2 wire” and “3 wire” pump is based on the type of motor that is used. A “3 wire” single phase submersible pump motor requires a control box or start box that contains  a starting capacitor or start/run capacitor. This box is normally mounted near the power

Lowara bore start box
Lowara bore start box

source or buildings meter box. This has an on/off manual switch and motor running indicator. On installation an electrician puts a 24v relay in this to accept the signal from a reticulation controller if required, thereby automating the start box. Because of the method of starting, the motor requires three “hot” leads (plus a lead for the ground connection) to operate correctly. It is called a “3-wire” due to the three “hot” leads, though there are actually 4

individual wires when you count the earth (ground) wire. On the other hand a “2 wire” motor requires no control/start box because it does not use a starting capacitor.

Sumoto Submersible Start Box
Sumoto Submersible Start Box

Instead, a “2 wire” motor has a built-in electrical device that is used to start the motor. This only requires the pump to have 2 “hot” leads (plus earth), which is why it is called a “2 wire” pump.  But when counting the total number of wires coming to the surface we see a “2 wire” pump actually has 3 wires and a “3 wire” pump actually has 4  wires. Confused?  Fixing submersible bores and pumps is what we do every day.  Our experience is what sets us apart. Our service teams have the knowledge, experience and tools to get the job done right first time with a minimum of fuss. Call 9246 0111 for any bore service needs Perth and surrounds or book a bore service online

Water Bore Fusion Insurance Claims

With the ending of Perth metro sprinkler bans for 2013  Perth bore owners are testing their water bores for the first time this season……and some aren’t working! We have had calls today all with similar stories. “I’m starting my bore and the circuit breaker is tripping ( or fuse is blowing), what do I do?”. First thing is we send a bore electrician ( one who is experienced in pumps and bores ) with special equipment to test the circuits and windings of the motor. With submersible motors this can be done without winching the pump up. Remember if it is a fused bore pump motor it may be covered under household insurance. Also if the fault can be traced back to one of winters electrical storms it may be related, even damage from lightning induction, and this too may be subject to an insurance claim. This is a very good reason to have the matter attended to first by specialist bore repairers who can correctly diagnose the fault and possible cause. 1300 734 300 will reach us 24/7