Old well lost prime Rivervale

 

This old style well in Rivervale has stopped pumping water and has lost prime. We got a call  on 9246 0111 from a client on Sunday who is selling his investment property in Rivervale.

His old style well in Rivervale has stopped pumping water with the he pump running  but no water was coming out. “My bore sounds like it is doing something – very noisy but no water coming out”. The homeowner kindly sent us some pics of the bore pump and well to help us work out the problem.

It is most likely a priming issue of some description. An air leak in the pump is a possibility as the client said the Perth bore pump ran dry for a while. This causes the metal housing to overheat which in turn can heat up the PVC pipe and distort it breaking the threaded seal and letting air in.

The cause may be a failed check valve, leak in the down borehole pipe or it may even be too far to the groundwater level in Rivervale at this time of year.

We will attend Rivervale on Monday and sort the problem as the client is in the process of selling the house. If we can help you with fixing an old well in Rivervale, Kewdale, Belmont or surrounds call on 9246 0111.

All service pumps, wells or bores anywhere in Perth. Happy to take your call 7 days a week or book an online service HERE

Old well lost prime
Old well lost prime
Stalker pump in well
Stalker pump in well

Happy bore service customers.

Thanks very much to two bore service customers, Frank and Mike, for the great comments on the jobs we recently completed for them. We will pass the excellent feed-back onto our team. If one of our bore service team can help you call on 9246 0111.

Happy customer
Happy customer

Good afternoon

Just confirming that I have paid your account.

We would like to thank you all for the very prompt and efficient service. We were absolutely thrilled with your response to our initial enquiry, the no fuss follow up to look at the problem and the very quick and professional way you have handled the situation.

Its a long time since we dealt with tradesmen who have delivered on their promise – and more.

We would certainly not hesitate to recommend your services and will ensure that your company is added to our preferred list of contractors for our local club

Sincerely
Mike

Fix old style well Perth

Old style well
Old style well

We are available to help out anytime. Today is a public holiday Monday and we were able to help out when Wayne called with a question about an old well south of the river. He rang us on 9246 0111.
Wayne has an old well style bore which is one liner deep. He had removed the sprinkler to flush out a line of accumulated debris. The pump was running but he wasn’t getting any water. Unfortunately he had run the pump at a flow higher than the bore could sustain. We explained to Wayne over the phone how to prime his “orange” pump and he was set to go. That was good news as he had just sold his house and needed his bore and retic working before settlement next week. He was going to get back to us if there were any further issues with his well.
If we can help with an old style well phone one of our team on 9246 0111.

New water bore Ballajura

Water bore problem Ballajura
Stuffed water bore Ballajura

It was a busy day in Ballajura today. We got called to a couple of bore electrical problems which we sorted quite quickly. We couldn’t immediately help the last call though.

The gentleman had a submersible bore that was of dubious construction. Not only was the borehole itself drawing sand, something which incidentally does not happen if the correct screens and gravel packing is used, but also the submersible pump was stuck irretrievably down the bore hole. The submersible pump had been installed down the bore without a stainless steel draw wire. The owner had erected a tripod and attempted to retrieve the pump by hauling up the poly pipe on a block and tackle. Unfortunately the poly pipe had snapped some metres down the bore hole and the poly pipe and submersible pump were now completely stuck.

Next week we will be drilling a new water bore for him. We’ll be sure to do everything to best practice standards to avoid problems like this in the future. We suspect this original bore had been a DIY or at best done by a backyard operator. Make sure if you are having a bore drilled in Ballajura or surrounds you use a licensed driller and preferably one who is a member of the ADIA.

If you would like a quote on a new water bore or need repairs to your existing bore in Ballajura give Virgin Bores a call on 92460111 or visit http://www.virginbores.com.au

Why is my old Perth bore running out of water?

Some Perth bore owners are telling us their very old water bores are running out of water or that it runs for a minute or two then it runs out.  We can help on 9246 0111.

This can be a a problem with the reticulation system or with the pump.

Slotted PVC bore casing
Slotted PVC bore casing

 

Commonly it is an issue with the yield of the bore itself and the pump is pumping water out faster than it is flowing in to the bore casing.

Many people think the bore is not deep enough. At times the water table does drop & it is a depth related issue. More often the stainless steel bore screen or slotted PVC bore casing has become blocked. Sometimes the ground around the bore has reduced the water it will “allow” to flow through it.

We would try air-developing, a process where large volumes of compressed air are pumped down the bore. We can also chemically clean and restore the bore with a combination of special cleaning compounds, surfactants and clay dispersants.

If your old Perth water bore is running out of water call us on 9246 0111 and we will talk through the problem or book a service online

Water bore faulty Perth

The sprinkler bans in Perth end at the end of August. We encourage you to only start using your Perth sprinklers when the garden needs it.

Perth bore owners have been out testing their water bores for the first time this spring. Some are faulty!

Electrical fault water bore
Bore electrical specialist working on submersible bore

We are hearing similar stories like  “I’m starting my bore and the circuit breaker is tripping or fuse is blowing, what should I do?”. We would send our specialist bore electrician Dave who has been doing this for years and is expert and experienced with water bores. He has special equipment to test the circuits & windings of the motor. We can do this without winching the pump up.

We remind our customers that if it is a fused bore pump motor it may be covered under household insurance. Also if the fault is storm related even damage from lightning induction that then this too may be subject to an insurance claim.

Submersible water bore from surface
Top of submersible water bore

To have the matter attended to first by specialist bore repairers who can correctly diagnose the fault and possible cause call the team on 9246 0111 or book an online service and read more about faulty water bores HERE

Unorthodox bore electrical work

We won’t tell you where in Perth our service man came across this unorthodox bore and reticulation interface but it was north of the river.

The reticulation controller was an indoor model mounted outside. It “talked” to the 24 volt relay that turned on the old well style centrifugal pump. We were called because the old bore had stopped pumping water.

In this case ultimately the best solution was to replace the old well with a new style submersible style bore in the northern suburbs home. This was done by our Perth bore drilling arm Virgin Bores. Check out our website www.virginbores.com.au.

If you would like a quote for a new submersible water bore in any Perth suburb call one of our friendly team on 9246 0111

Unorthodox bore & reticulation interface
Unorthodox bore & reticulation interface

Broken Bore Pump Dalkeith

Liana in Dalkeith needed her water bore repaired and called us on 9246 0111.

Our specialist bore electrician tested the circuits and found her 1.1 kw three phase submersible pump motor was fused. We replaced it with a new submersible pump motor and tested all OK.

Thanks for your positive feedback.

Hi Brett,

I have just had Adam here this morning dealing with our seized bore, just wanted to let you know he was such a great representative of the company,very professional and followed the job through very efficiently!! I also spoke with Troy on the Phone and they had the whole problem fixed with in two days, with the help of Dave the electrician.

Thanks again it was a pleasure to deal with such a professional company, (I have already let my gardener know, should any of his clients need your assistance!!!)

regards Liana

If you would like to talk to one of our team call 9246 0111 or go to our main website on HERE

Thanks Bore Electrician Kewdale and Pump Replacement Carine

It is great to hear from happy customers and hear good reviews. Thank you! 9246 0111

Thanks for sending our specialist bore electrician to Kewdale
Thanks for sending our specialist bore electrician to Kewdale

Our experienced bore electrician Dave attended Russell’s Kewdale property, checked his system and supplied and fitted a new reticulation controller.

We also attended Philip’s Carine property where we replaced his .75 kw 2 wire submersible motor / pump and tested that everything was OK.

“Thank you for your teams excellent work just prior to Christmas. Having the bore operational again has been fantastic. Once again thank you and I am happy to recommend your services to anyone. Regards Phillip.”

If we can assist you with specialist bore electrical advise or pump replacement visit our website  HERE or phone Troy (ask him how his fishing is going) on 9246 0111

Automation of Old Well

This old well with a tin lid has been running without a retic controller. We are going to automate this old well in Morley.

We will fit an automatic reticulation controller and interface to the clients existing on/off switch. We then replace the manual bore valves (in the foreground of the picture) with automatic solenoid valves.

Hey presto, it will come on automatically and switch from front to rear lawns and it is fully programmable.

If we can help you with a similar issue or anything to do with your bore or reticulation contact one of our friendly team on 9246 0111 or go to our website HERE

Automate old well
Automate old we