Don lives in Bibra Lake and the new pump in his old well was not pumping water.
He had rung several companies and it seems all they saw was $$$.
He then rang Brett, who started Virgin Bores nearly 20 years ago, and is very knowledgeable about most things that can go wrong with a bore or old style well.
Brett talked through with Don over the phone how to prime his pump. It took a lot of water to top prime but it worked on the third attempt. Although there wasn’t much water coming out at first once the pipes had filled at the front and back of the house the pump changed sound and was really working.
Thanks Don we appreciate the great feed-back for Virgin Bores
Don told us that if he had any future problems or repairs he would call Virgin Bores on 9246 0111.
Don, thanks for the great review. We always try and put the customer first. If we can help you with repairs to your older style call us for expert advise on 9246 0111.
Pictured is a pressure release valve or they can be referred to as a pressure relief valve. It is designed to open and release water if the pump is started and the water has nowhere to go.
They are often used when we install a tap connected to a water bore. The valve is spring-loaded and set to open if there are any mishaps with the bore pump running and the tap being accidentally closed.
Also if your solenoid valves in your water bore reticulation fail to open and the pump is running the Pressure Release Valve allows the water to escape and helps prevent damage.
Pressure Release Valves are either preset or calibrated and adjustable. If the submersible pumps is run whilst the water flow is overly restricted or shut off (dead-headed) there could be overheating of the pump motor, in turn causing the rising poly main which carries the water up from the pump to get hot blowing a hole in the side of the softened pipe.
If your water bore needs repair in the Perth area call us on 9246 0111 or book an online service HERE
We work for many real estate agents in Perth servicing and maintaining the water bores for their rental properties. We are sent a maintenance work order when a water bore isn’t working and we liaise with the tenants to repair the water bore.
Como Bore Fixed
We were asked last week to get our electrician to check a bore at a rental property in Como. The electrics were fine but it was not pumping water. Dave had to search around this corner block and eventually found a conduit and pump cable going to ground in the carport. He uncovered the tell-tale green lid of a submersible bore.
Conduit and submersible pump cable found near carport
He found there was no water at the top of the bore head. We returned and winched up the submersible pump and replaced some blown poly.
Flat retic controller battery
Some detective work by Dave uncovered that the mains power had gone off and the reticulation controller had auto reset for 10 minutes into all stations and the pump had been dead-heading. Non existent stations had been turning on the pump with nowhere for the water to go. This had caused the poly rising main to blow near the submersible pump. All caused because the back up battery had been flat and not preserved the program memory. We replaced the flat 9 volt retic controller battery for new. We also looped out the unused stations to prevent this happening again.
Both the tenant and the property owner are happy and the water bore at the Como property is up and running. If your water bore or retic system needs repair or service in the Como or South Perth area call Troy on 9246 0111 or book a bore service here
A resident of South Perth was concerned as their reticulation was not working and they contacted us on 9246 0111.
They reported that they could hear the typical “çlunk” sound as the contactor engaged when they started the bore pump from their retic controller.
Our electrician found that the one horsepower Sumoto submersible motor was not fused. The motor windings appeared to be intact but there was a complete dead short to earth.
His recommendation was that we replace the submersible motor, wet-end and electrical cable down the bore hole for new. He disabled and taped up motor tails in the borehead junction box and all the other electrics tested OK.
See the bore start box to the left of the retic controller
So another member of the team returned and replaced the .75KW submersible motor, 15 metres of electrical and stainless and barrell union. All tested OK and another South Perth water bore was back up and running for the hot summer months ahead.
When there is a problem with a water bore it takes experience and skill to diagnose the problem and repair efficiently, quickly and economically for the Perth householder.
We have been repairing Perth water bores for 20 years and have been faced with most problems when repairing a water bore, Call us on 9246 0111 or book a bore service here
Earlier this month our specialist bore electrician went to a client’s home in Bassendean to test a three phase centrifugal pump motor. It was reported that the bore was not working.
The pump was running but there was no water. It was a 2 liner well on the right hand side of the driveway.
Old style well in Bassendean needs priming
We primed the well and all is working OK and tested OK.
Testing pump after repair of Bassendean old style well
If you have an old style well with a tin lid in the Bassendean area or the surrounding areas of Beechboro or Bayswater that is in need of repair we are the experts after nearly 20 years in the business.
A client in Fremantle wanted us to look at his water bore. The brick pit around the top of the bore certainly confirmed that this was indeed a very early submersible bore. He was told he had old casing that had been breached that was no good. He wanted a second opinion.
We test pumped the water bore at 80 litres a minute for 35 mins and found the bore water was very dirty for the first 5 minutes. For 30 minutes it then pumped flawlessly. Good flow and clear bore water.
Very early submersible bore East Fremantle
Our serviceman’s notes brought a smile to the customer’s face. It appears the initial diagnosis had been wrong.
“10:30-12:00 Test pumped at 80lpm for 35 mins Was very dirty for five mins
Small amount of plant matter coming up could be from dirt that had fallen from above ground”
It’s a good bet that this bore will run for a good many more years after we install a new submersible pump.
We have been in Kingsley testing a 1.5 kw Red Jacket pump motor after Daryl rang us with problems with his submersible water bore. It has given faithful service as it is approximately 24 years old.
Check out the burnt out junction box in this bore in Kingsley. Down hole is a submersible Red Jacket pump.
Ultimately the pump motor tested OK for our specialist bore electrician Dave but the original tests read dead short to earth. He found that the junction box in the borehead was completely burnt out. Dave replaced the junction box for new and all is working again. He did a Tong Test which was at 11 amps well within range.
Initial tests on this submersible bore showed a dead short to earth suggesting that the Red Jacket pump motor had failed.
Dave drilled several holes in the bottom of the junction box to allow water to drop out and not fill up in the future.
We have drilled and repaired a number of modern submersible water bores in the Kingsley area and the surrounding suburbs of Padbury and Woodvale so we understand the ground water conditions in the area. Call us on 9246 0111 or go to our website HERE
James from Mount Pleasant phoned regarding his submersible pump that was tripping the circuit breaker. (Call us anytime on 9246 0111 if you need help too)
The water bore was drilled in his driveway and it was very useful to know that the paver to show where the bore was located was a different color. As pictured the bore head was was covered by an old concrete lid pit.
Head of submersible water bore under pavers in driveway
Our senior experienced bore electrician Dave reported the motor was about 8 years old. The 1.1 kw 2 wire subbie motor was dead short to earth and although the motor’s windings appeared to be intact the internal capacitor had ruptured. So we replaced it with a new 1.1 kw sunbmersible pump motor and replaced the start box and junction box.
We replaced the junction box too. This joins the cables coming up from the pump to the cables going to the house.
We have drilled and repaired many water bores in Mt Pleasant, Applecross, Bateman Ardross and surrounds. We are very experienced with the conditions in the area. If your water bore or retic is in need of repair call us on 9246 0111 or check out our main website HERE
The centrifugal pump motor down this well in Thornlie is seized up mechanically.
Our specialist bore electrician, Dave, reported it was drawing over 52 amps. The Thornlie pump motor is one well liner down in the backyard if the Thornlie house.
We will now send another member of the team to replace the centrifugal pump and replace the blown fuse wire.
This Thornlie resident will soon be ready for summer.
If you have an old-style well we are the people to repair it! So if you are in the Thornlie area or the surrounding suburbs of Langford or Parkwood call us on 9246 0111.
Our mobile service teams do prompt repairs to ALL TYPES of Water Bores & Reticulation Sprinkler Systems Perth metro-wide. Free phone advice. Our experience saves you time and money. Bore repair HOTLINE 1300 734 300 North of River: Troy 0408454130 South of River: Brett 0411511611